The maximum diameter measured over the insulation is 2.06mm and the conductor range for the connector is 0.4to 0.9mm or 26 to 19AWG.
Designed for applications covering aerial , buried and underground construction which are exposed to a full range of temperature , humidity and pollutants. Filled with sealant ensuring excellent insulation resistance and electrical performance in the most stringent environmental conditions
With full compliance to the BTLN 363C specification to be undertaken and verified by BT Openreach the Polypropylene material for the base and cover has excellent properties, high tensile strength, good chemical resistance and resistance to cracking in low working temperatures, good impact resistance and finally high clarity for visual inspection of the crimped splice. Will work with Conductor type solid copper or aluminium alloy and capable of being used with paper, solid polyethylene, or cellular polyethylene insulation.
Adopting and establishing a working practise to use and encourage the use of test probes rather than using crocodile clips or nicking the cable insulation to test will significantly reduce Shiners.
Long term the reduction in Shiners will improve Network Reliability and significantly reduce Truck Rolls.