AlarmSense Optical Smoke Detector and Sounder Visual Indicator Base (55000-394APO)

Product images are for illustrative purposes only. Colours, sizes and weights may differ from the actual product and subject to change without notice.

AlarmSense Optical Smoke Detector and Sounder Visual Indicator Base (55000-394APO)


  • £5.40
  • Shipping calculated at checkout.
(£4.50 excluding VAT)

Only 0 left!
Will be in stock after

An AlarmSense Optical Smoke Detector and Sounder Visual Indicator Base (55000-394APO).

Optical Smoke

  • A high quality optical detector.
  • Suitable for use with C-TEC's CFP AlarmSense range of 2-8 Zone Two-Wire Fire Panels.
  • Housed in a pure white polycarbonate moulding.
  • Fitted with two alarm LEDs to allow 360º visibility.
  • Third-party certified to EN54-7 by UL International (UK) Limited.
  • 9-33V DC operating voltage.
  • Requires a 45681-244APO AlarmSense base.
  • Can also be purchased as part of a detector/sounder or detector/sounder visual indicator base combination.

Sounder Visual Indicator Base

  • Will accept any AlarmSense fire detector to provide fire detection and an audible AND visual alarm warning signal at the same point.
  • 70d-87dB(A) sound output (visual indicator activates with sounder).
  • Certified to EN54-3 by UL International (UK) Limited.
  • Suitable for use with C-TEC's CFP AlarmSense range of 2-8 Zone Two-Wire Fire Panels.
  • AlarmSense priority/non priority signal recognition
  • Detects the removal of a detector head and reports a fault
  • Continues to work during unauthorised removal of detector.
  • High and low volume ranges.
  • Red and white caps available for stand-alone use.
  • Can also be purchased as part of a detector/sounder visual indicator base combination.
Technical

Optical Smoke

Approvals/certifications Certified to EN54-5 by UL International (UK) Limited
Application/operation Generates an alarm condition when it detects a pre-set threshold of smoke penetration into the smoke chamber
Supply wiring 2-wire monitored, polarity insensitive
Supply/operating voltage 9 to 33V DC
Quiescent current 50µA @ 15 VDC
Alarm voltage 9 to 33V DC
Alarm current 1.5mA @ 2-8.5V; 25 +/- 2mA @ 10.5-15V; 1.5AmA @ 18-24V; 2mA @ 33V
Alarm reset voltage 2V max (1 second alarm reset time)
Product dimensions (mm) 100mm diameter x 42m deep (detector only); 100mm diameter x 50mm deep (detector in base)
Construction & finish White polycarbonate
IP Rating TBC
Weight 100g

 

Sounder Visual Indicator Base

Approvals/certifications Certified to EN54-5 by UL International (UK) Limited
Application/operation Designed to be ceiling mounted with an AlarmSense fire detector. Red and White caps available for stand alone use
Supply wiring 2-wire monitored, polarity insensitive
Supply/operating voltage 9 to 33V DC
Quiescent current Less than 20µA @ 12VDC
Alarm voltage 9 to 33V DC
Nominal SPL (Sound Pressure Level) 87dB(A) max (high volume setting); 70dB(A) nominal (low volume setting)
Alarm current 5mA (sounder active current at 24V)
Product dimensions (mm) 1115mm diameter x 40mm deep (without optional AlarmSense detector)
Construction & finish White/clear polycarbonate. Red and white caps available if not use with an AlarmSense fire detector
IP Rating TBC
Weight 100g

 